Show external content

To display this content, you must explicitly agree to the loading of „External content“.

SILENT powerCAM EC

Extraction unit for CAM systems

Powerful, bag-free extraction unit with automatic filter cleaning and EC motor technology for heavily used CAM units.

Advantages

  • Bi-directional communication between extraction unit and CAM unit thanks to the PLC interface.
  • Low operating noise of max. 54.3 dB (A).
  • Reliable production process through brushless EC motor technology (guaranteed runtime of 5000 operating hours).

Details

  • High volume flow of approx. 4000 l/min.
  • No follow-up costs due to bag-free dust collection.
  • Safe disposal of fine milling dust with the help of a disposal bag.

SILENT powerCAM EC, 220-240 V

Item number 29390000
Scope of delivery:
SILENT powerCAM EC, Quick Start Guide, Quick Reference Card, 3 disposal bags (1 pc. inserted in the dust drawer), suction hose 2 m, incl. 2 mufflers

SILENT powerCAM EC, 120 V

Item number 29391000
Scope of delivery:
SILENT powerCAM EC, Quick Start Guide, Quick Reference Card, 3 disposal bags (1 pc. inserted in the dust drawer), suction hose 2 m, incl. 2 mufflers

SILENT powerCAM EC, 100 V 50/60 Hz

Item number 29392000
Scope of delivery:
SILENT powerCAM EC, Quick Start Guide, Quick Reference Card, 3 disposal bags (1 pc. inserted in the dust drawer), suction hose 2 m, incl. 2 mufflers
SILENT powerCAM EC, 220-240 V SILENT powerCAM EC, 120 V SILENT powerCAM EC, 100 V 50/60 Hz
Item number 29390000 29391000 29392000
Use Extraction unit for CAM systems Extraction unit for CAM systems Extraction unit for CAM systems
Permissible mains voltage 220 - 240 V 120 V 100 V
Permissible mains frequency 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz
Weight (empty) 18 kg
39.7 lbs
18 kg
39.7 lbs
18 kg
39.7 lbs
Dimensions (W x H x D) 270 x 535 x 540 mm
10.6 x 21.1 x 21.2 "
270 x 535 x 540 mm
10.6 x 21.1 x 21.2 "
270 x 535 x 540 mm
10.6 x 21.1 x 21.2 "
Power consumption 1,610 hp 1,440 hp 1,250 hp
Nominal voltage 230 V 120 V 100 V
Volume flow (max.) 3,984 l/min
2.34 ft³/s
3,984 l/min
2.34 ft³/s
3,984 l/min
2.34 ft³/s
Max. depression 257 hPa
3.73 psi
262 hPa
3.8 psi
255 hPa
3.7 psi
Motor technology EC EC EC
Filter technology Bag- free Bag- free Bag- free
Filter quality Class M according to EN 60335-2-69 Class M according to EN 60335-2-69 Class M according to EN 60335-2-69
CAM interface RJ 45 socket RJ 45 socket RJ 45 socket
Mains input fuse 2 A(T) 2 A(T) 2 A(T)
Number of suction hoses 1 1 1
Sound pressure level (LpA) (at max. volume flow) 54.3 dB(A) 54.3 dB(A) 54.3 dB(A)
Ø suction fittings interior 42 mm
1.65 "
42 mm
1.65 "
42 mm
1.65 "
Fill level dust collector 7 l
1.85 gal
7 l
1.85 gal
7 l
1.85 gal
Item number
29390000
Use
Extraction unit for CAM systems
Permissible mains voltage
220 - 240 V
Permissible mains frequency
50 - 60 Hz
Weight (empty)
18 kg
39.7 lbs
Dimensions (W x H x D)
270 x 535 x 540 mm
10.6 x 21.1 x 21.2 "
Power consumption
1,610 hp
Nominal voltage
230 V
Volume flow (max.)
3,984 l/min
2.34 ft³/s
Max. depression
257 hPa
3.73 psi
Motor technology
EC
Filter technology
Bag- free
Filter quality
Class M according to EN 60335-2-69
CAM interface
RJ 45 socket
Mains input fuse
2 A(T)
Number of suction hoses
1
Sound pressure level (LpA) (at max. volume flow)
54.3 dB(A)
Ø suction fittings interior
42 mm
1.65 "
Fill level dust collector
7 l
1.85 gal
Item number
29391000
Use
Extraction unit for CAM systems
Permissible mains voltage
120 V
Permissible mains frequency
50 - 60 Hz
Weight (empty)
18 kg
39.7 lbs
Dimensions (W x H x D)
270 x 535 x 540 mm
10.6 x 21.1 x 21.2 "
Power consumption
1,440 hp
Nominal voltage
120 V
Volume flow (max.)
3,984 l/min
2.34 ft³/s
Max. depression
262 hPa
3.8 psi
Motor technology
EC
Filter technology
Bag- free
Filter quality
Class M according to EN 60335-2-69
CAM interface
RJ 45 socket
Mains input fuse
2 A(T)
Number of suction hoses
1
Sound pressure level (LpA) (at max. volume flow)
54.3 dB(A)
Ø suction fittings interior
42 mm
1.65 "
Fill level dust collector
7 l
1.85 gal
Item number
29392000
Use
Extraction unit for CAM systems
Permissible mains voltage
100 V
Permissible mains frequency
50 - 60 Hz
Weight (empty)
18 kg
39.7 lbs
Dimensions (W x H x D)
270 x 535 x 540 mm
10.6 x 21.1 x 21.2 "
Power consumption
1,250 hp
Nominal voltage
100 V
Volume flow (max.)
3,984 l/min
2.34 ft³/s
Max. depression
255 hPa
3.7 psi
Motor technology
EC
Filter technology
Bag- free
Filter quality
Class M according to EN 60335-2-69
CAM interface
RJ 45 socket
Mains input fuse
2 A(T)
Number of suction hoses
1
Sound pressure level (LpA) (at max. volume flow)
54.3 dB(A)
Ø suction fittings interior
42 mm
1.65 "
Fill level dust collector
7 l
1.85 gal

Technical data

SILENT powerCAM EC, 220-240 V SILENT powerCAM EC, 120 V SILENT powerCAM EC, 100 V 50/60 Hz
Item number 29390000 29391000 29392000
Use Extraction unit for CAM systems Extraction unit for CAM systems Extraction unit for CAM systems
Permissible mains voltage 220 - 240 V 120 V 100 V
Permissible mains frequency 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz
Weight (empty) 18 kg
39.7 lbs
18 kg
39.7 lbs
18 kg
39.7 lbs
Dimensions (W x H x D) 270 x 535 x 540 mm
10.6 x 21.1 x 21.2 "
270 x 535 x 540 mm
10.6 x 21.1 x 21.2 "
270 x 535 x 540 mm
10.6 x 21.1 x 21.2 "
Power consumption 1,610 hp 1,440 hp 1,250 hp
Nominal voltage 230 V 120 V 100 V
Volume flow (max.) 3,984 l/min
2.34 ft³/s
3,984 l/min
2.34 ft³/s
3,984 l/min
2.34 ft³/s
Max. depression 257 hPa
3.73 psi
262 hPa
3.8 psi
255 hPa
3.7 psi
Motor technology EC EC EC
Filter technology Bag- free Bag- free Bag- free
Filter quality Class M according to EN 60335-2-69 Class M according to EN 60335-2-69 Class M according to EN 60335-2-69
CAM interface RJ 45 socket RJ 45 socket RJ 45 socket
Mains input fuse 2 A(T) 2 A(T) 2 A(T)
Number of suction hoses 1 1 1
Sound pressure level (LpA) (at max. volume flow) 54.3 dB(A) 54.3 dB(A) 54.3 dB(A)
Ø suction fittings interior 42 mm
1.65 "
42 mm
1.65 "
42 mm
1.65 "
Fill level dust collector 7 l
1.85 gal
7 l
1.85 gal
7 l
1.85 gal
Item number
29390000
Use
Extraction unit for CAM systems
Permissible mains voltage
220 - 240 V
Permissible mains frequency
50 - 60 Hz
Weight (empty)
18 kg
39.7 lbs
Dimensions (W x H x D)
270 x 535 x 540 mm
10.6 x 21.1 x 21.2 "
Power consumption
1,610 hp
Nominal voltage
230 V
Volume flow (max.)
3,984 l/min
2.34 ft³/s
Max. depression
257 hPa
3.73 psi
Motor technology
EC
Filter technology
Bag- free
Filter quality
Class M according to EN 60335-2-69
CAM interface
RJ 45 socket
Mains input fuse
2 A(T)
Number of suction hoses
1
Sound pressure level (LpA) (at max. volume flow)
54.3 dB(A)
Ø suction fittings interior
42 mm
1.65 "
Fill level dust collector
7 l
1.85 gal
Item number
29391000
Use
Extraction unit for CAM systems
Permissible mains voltage
120 V
Permissible mains frequency
50 - 60 Hz
Weight (empty)
18 kg
39.7 lbs
Dimensions (W x H x D)
270 x 535 x 540 mm
10.6 x 21.1 x 21.2 "
Power consumption
1,440 hp
Nominal voltage
120 V
Volume flow (max.)
3,984 l/min
2.34 ft³/s
Max. depression
262 hPa
3.8 psi
Motor technology
EC
Filter technology
Bag- free
Filter quality
Class M according to EN 60335-2-69
CAM interface
RJ 45 socket
Mains input fuse
2 A(T)
Number of suction hoses
1
Sound pressure level (LpA) (at max. volume flow)
54.3 dB(A)
Ø suction fittings interior
42 mm
1.65 "
Fill level dust collector
7 l
1.85 gal
Item number
29392000
Use
Extraction unit for CAM systems
Permissible mains voltage
100 V
Permissible mains frequency
50 - 60 Hz
Weight (empty)
18 kg
39.7 lbs
Dimensions (W x H x D)
270 x 535 x 540 mm
10.6 x 21.1 x 21.2 "
Power consumption
1,250 hp
Nominal voltage
100 V
Volume flow (max.)
3,984 l/min
2.34 ft³/s
Max. depression
255 hPa
3.7 psi
Motor technology
EC
Filter technology
Bag- free
Filter quality
Class M according to EN 60335-2-69
CAM interface
RJ 45 socket
Mains input fuse
2 A(T)
Number of suction hoses
1
Sound pressure level (LpA) (at max. volume flow)
54.3 dB(A)
Ø suction fittings interior
42 mm
1.65 "
Fill level dust collector
7 l
1.85 gal

Suction hose

Item number 900034240
Scope of delivery:
3 m (with 2 mufflers)

Suction hose

Item number 901150823
Scope of delivery:
6 m

Suction hose

Item number 902150823
Scope of delivery:
9 m

Suction hose, antistatic

Item number 900034826
Description:

antistatic

Scope of delivery:
3 m (with 2 mufflers)

Universal adapter for suction hose

Item number 900034430
Scope of delivery:
1 piece

Adapter for hose connection

Item number 900034305
Description:

Suitable for most common sized hoses. Accurately fitting connection without cutting to size.

Scope of delivery:
1 piece

90° angled connector

Item number 29340007
Scope of delivery:
1 piece

End bushings set

Item number 29210003
Scope of delivery:
set (2 pieces)

Interface cable Type A for vhf

Item number 29340005
Description:

for vhf, 4-pin

Scope of delivery:
5 m

Interface cable Type B for Roland DG

Item number 29340006
Description:

for Roland DG

Scope of delivery:
5 m

Interface cable Type C for imes-icore

Item number 29340008
Description:

for imes-icore

Scope of delivery:
5 m

Interface cable Type D for Amann Girrbach

Item number 29340009
Description:

for Amann Girrbach

Scope of delivery:
5 m

Interface cable Type E for Yenadent

Item number 29340010
Description:

for Yenadent

Scope of delivery:
5 m

Interface cable Type F for Zirkonzahn

Item number 29340011
Description:

for Zirkonzahn

Scope of delivery:
5 m

Interface cable Type G for vhf

Item number 29340013
Description:

for vhf, 6-pin

Scope of delivery:
5 m

Interface cable Type H for Dentsply Sirona

Item number 29340016
Description:

for Dentsply Sirona

Scope of delivery:
5 m

Interface cable Type I for Up3D

Item number 29340017
Description:

for Up3D

Scope of delivery:
2,5 m

Interface cable Type J for Canon

Item number 29340018
Description:

for Canon

Scope of delivery:
5 m

Interface cable Type K for DGShape

Item number 29340019
Description:

for DGShape

Scope of delivery:
2 m

Interface cable Type F for Zirkonzahn + C14 adapter

Item number 29340012
Description:

for Zirkonzahn with C14 adapter

Scope of delivery:
5 m

External ventilation SILENT TC/TC2/EC2/powerCAM EC

Item number 29370002
Description:

External ventilation with three possible outlets (to the right, left and back), incl. 2 m outlet tube.

Scope of delivery:
Adapter incl. Ø100 mm plastic tube, 2 m

Silencer

Item number 29560000
Description:

Up to 50% reduction of the perceptible extraction noise, with constant suction power. Quick and easy installation on the suction hoses. We recommend aligning the Silencer vertically to obtain the full performance of noise reduction.

Scope of delivery:
1 piece

Fine filter class M SILENT EC2, powerCAM EC

Item number 900021584
Description:

Fine filter, class M (DIN EN 60335-2-69)

Scope of delivery:
Set consisting of fine filter and exhaust air filter

Waste bag SILENT TC, TC2, EC2 & powerCAM EC/TC

Item number 29340014
Description:

Matching HDPE waste bags for replacement.

Scope of delivery:
25 pieces

Starter kit waste bag SILENT TC, TC2, EC2 & powerCAM EC/TC

Item number 29340015
Description:

Easy to retrofit! Enables low dust disposal of the collected particles.

Scope of delivery:
1 x magnetic fastening ring, 25 x HDPE waste disposal bags

Schnittstellenkabel type M for XTCERA

Item number 29340021
Description:

for XTCERA

Scope of delivery:
5 m

SILENT powerCAM EC, 220-240 V

Item number 29390000

View spare parts list

SILENT powerCAM EC, 120 V

Item number 29391000

View spare parts list

SILENT powerCAM EC, 100 V 50/60 Hz

Item number 29392000

View spare parts list
  • Repair manual

    SILENT powerCAM EC 2939x000
    PDF (23.76MB)
    Multilingual
  • Declaration of conformity

    SILENT powerCAM EC 2939x000
    PDF (413KB)
    Multilingual
  • Declaration of conformity

    UKCA SILENT
    PDF (385KB)
  • Instruction manual

    SILENT powerCAM EC 2939x000
    PDF (12.86MB)
    Multilingual
  • Quick Start Guide

    SILENT powerCAM EC 2939x000
    PDF (10.31MB)
    Multilingual
  • FAQ

    SILENT powerCAM EC 2939x000
    PDF (1.16MB)
    Multilingual
  • Product navigator

    Product navigator

    Product navigator

    Product navigator

    Product navigator

    Product navigator

    Product navigator

    Renfert CAM Guide
    Renfert CAM Guide
    Renfert CAM Guide
    Renfert CAM Guide
    Renfert CAM Guide
    Renfert CAM Guide
    Renfert CAM Guide
    PDF (1.25MB)
    PDF (1.25MB)
    PDF (1.25MB)
    PDF (1.25MB)
    PDF (1.25MB)
    PDF (1.25MB)
    PDF (1.25MB)
  • Product navigator

    Product navigator

    Product navigator

    Product navigator

    Product navigator

    Product navigator

    Product navigator

    SILENT Product Navigator | Offline PDF
    SILENT Product Navigator | Offline PDF
    SILENT Product Navigator | Offline PDF
    SILENT Product Navigator | Offline PDF
    SILENT Product Navigator | Offline PDF
    SILENT Product Navigator | Offline PDF
    SILENT Product Navigator | Offline PDF
    PDF (783KB)
    PDF (780KB)
    PDF (770KB)
    PDF (768KB)
    PDF (771KB)
    PDF (775KB)
    PDF (772KB)
  • Catalogue

    RENFERT_CATALOG_EN.PDF
    PDF (29.53MB)

{- title -}

{- text -}

Show external content

To display this content, you must explicitly agree to the loading of „External content“.

Renfert Maintenance | Motor Change SILENT EC2

Show external content

To display this content, you must explicitly agree to the loading of „External content“.

Renfert Maintenance | Filter Change SILENT EC2

Customer reviews

“Thanks to the bagless fine filter technology with mechanical filter cleaning, the SILENT CAM extraction units by Renfert feature an enormous suction power that remains stable even over long periods of operation. With the SILENT extraction units, our CAM milling machines are top protected and can exploit their full potential.” www.zirkonzahn.com

“A milling machine can only perform at its best if the infrastructure is appropriate. A decisive component is a reliably and conveniently functioning extraction unit for dry milling. Innovative dental milling machines by vhf harmonize perfectly with the powerful SILENT CAM extraction units by Renfert, thus allowing the user to fully concentrate on his work.“

www.vhf.com

Armin Silginer
Head of R&D at Zirkonzahn
Björn Höppe
Head of Product at vhf